Subject to the connected components and s ettings you have made, you can scan
the actual temperatures and operating conditions.
Press the following keys:
Outdoor temp.
ºF
68
i
1.i for example, Outdoor temp.”
may be displayed.
If “Select htg. circuit”; is
displayed and “1r flas hes:
H Select that heating circuit
with / ,towhichthe
adjustment should apply.
H Confirm twice with
.
H Press i again.
2. / for further scanning of the list.
3.i to end s canning.
Order in which temperatures and operating conditions may be scanned
You can scan various current temperatures and operating s t atus information
depending on the system components and the settings.
H Subscriber no. -inconnectionwith
other control units
H H oliday program - (if entered) with
dates of departure and return
H Outdoor temperature
H Boiler water temperature
H F low temperature - for heating circuit
with mixing valve
H Normal room temp. -setvalue
H Room temperature - actual value only
if a remote control unit is connected
H Ext. Set room temp. - only if external
hook-up has taken place
H DHW temperature - DHW temperature
H Solar DHW temp. - DHW temperature
in solar mode (if used)
H Collector temperature -onlyifasolar
heating s y stem is connected
H Common flow temp. - common flow
temperature for sys t ems with low loss
header
H Burner*
1
- burner hours run
H Burner st arts*
1
H Solar energy - display in kWh (only if a
solar heating sy s tem is connected)
H Time
H Date
H Burner ON / OFF
H Int. pump ON / OFF (boiler pump)
H Int. output ON / OFF -forinternal
connection extension
H HeatingpumpON/OFF- for external
heating circuit pump for heating circuit
A1 (pump 20A)
H Tank pump ON / OFF (pump 21)
H C pump ON / OFF - DHW recirculation
pump (pump 28)
H Central fault m. ON / OF F - central
fault message (output 50)
H Mixing valve
Mixing valve open - fully open
Mixing valve - intermediate position
Mixing valve closed - f ully closed
H Solar circuit pump ON / OFF (not
used)
H Solar circuit pump ...hrs. - solar circuit
pump hours run (not used)
H Language
*1
To reset to “0” : Press
D
and confirm
with
.
5369 299 v1.0 b