Viesmann VITODENS 200-W Operations Instructions Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
Selecting DHW Heating
26
Selecting Constant DHW Heating (continued)
Selecting a time program (switching times)
Heating system without DH W
recirculation pump
DHW can be enabled / disabled up to
four times per day (four time phases).
Automatic mode is set in the time
program in t he factory. That means
DHW heating is enabled in parallel to
the central heating program of the first
available heating circuit, but starts
30 min. earlier (from 05:30 to
22:00 hrs.).
Should you not wish to operate in
automatic mode, you can also s et up
individual time programs. You can select
identical time programs for every day or
individual programs for each day.
When setting time programs, bear in
mind that your heating sys tem requires
some time to heat the DHW tank to the
required temperature.
For t ime programming steps, (see pages
26 and 27). For a sequence of steps to
deleteatimephase,(seepage28).
Heating sys tem with DHW recirculation
pump
The DHW recirculation pump transports
hot water through a circuit between the
DHW tank and the draw-off points to
deliver DHW to the t aps as quickly as
possible.
DHW heating and the DHW recirculation
pump can be enabled / disabled up to
four times per day (four time phases).
Automatic mode is set in the time
program at the factory. That means
DHW heating and the DHW recirculation
pump are activated in parallel to the
central heating program of the first
available heating circuit, but starts 30
min. earlier (from 05:30 to 22:00 hrs.).
Should you not wish to operate in
automatic mode, you can also s et up
individual time programs. You can select
identical time programs for every day or
individual programs for each day.
When setting time programs, bear in
mind that your heating sys tem requires
some time to heat the DHW tank to the
required temperature.
Also, enabling the DHW recirculation
pump is only sensible for those times
when DHW is actually drawn.
For time programming steps, (see pages
26 and 27). For a sequence of steps to
deleteatimephase,(seepage28).
Selecting automatic mode (if required)
Press the following keys:
1. uw for “DHW time program”.
2. / to select “DHW time
program”, or “ Recirc. pump
time program”.
3.
to confirm.
4. / for Automatic?”, if
“Automatic?” is not yet
displayed.
5.
to confirm.
5369 299 v1.0 b
Page view 25