Page view 26
Selecting DHW Heating
27
Selecting Constant DHW Heating (continued)
Setting up an individual time program
The following explains the setting up of a time program using DHW heating uw
as an example. F or the DHW recirculation pump t ime program, proceed as described
above, after you have selected “Recirc. pump time program”.
DHW time prog.
1-7
DHW time prog.
Mo
Press the following keys:
1. uw for DHW time program.”.
Note:
Ifyouwanttoterminatethetime
programming early,pressuw
again and confirm with
.
2. / to select “DHW time
program.”, or Recirc. pump
time program.”.
3.
to confirm.
4. / for Individual?”, if Individual?”
is not yet displayed.
5.
to confirm.
6. / until “1-7 is displayed, if you
want to set up the same time
phases for every day.
Or..
7. / until “Mo”, “Tu etc. is
displayed, if you want to set
different time phases for the
displayed day.
8.
to confirm; “DHW timer 1” will
then be displayed.
9.
to confirm; “DHW timer 1 ON”
will then be displayed.
10. /for DHW phase starting point.
11.
to confirm; “ DHW cycle 1 Off”
will be displayed.
12. /for DHW phase end point.
13.
to confirm; “ DHW cycle 2 On”
will then be displayed.
14. Proceed for s etting the start and
end of DHW phases 2 to 4 as
describedinsteps9to11.
Note:
If different time phases are set for
individual days and you want to
return to identical time phases for
every day, press
when “1-7 is
displayed.
All time phases a re ret urned to t heir
original delivered condition.
Note:
Press ifyouwanttoskipatime
phase.
5369 299 v1.0 b